Specifications

  • Product Name : Dräger Babylog VN600 Neonatal Ventilator
  • Brand : Draeger
  • Patient Category : Neonates, Pediatric Patients
  • Ventilation Modes : PC-CMV, PC-SIMV, PC-AC, PC-APRV, PC-PSV, PC-HFO, PC-MMV, SPN-CPAP/PS, SPN-CPAP/VS, SPN-CPAP, SPN-PPS
  • Ventilation Types : Invasive, Non-Invasive (NIV), O2 Therapy, High-Flow/NIV transitions
  • Respiratory Rate : 0.5 – 150 breaths/min
  • Inspiratory Time (Ti) : 0.1 – 3 s (neonates)
  • Tidal Volume (VT) : Neonates: 2 – 100 mL; Pediatric: 20 – 300 mL
  • Inspiratory Flow : Neonates up to 30 L/min; pediatric higher
  • Inspiratory Pressure : 1 – 80 mbar (cmH₂O)
  • PEEP : 0 – 35 mbar (cmH₂O)
  • FiO₂ Range : 21% – 100%
  • Trigger Threshold : 0.2 – 5 L/min
  • Display : 15.6″ Capacitive Touchscreen
  • Connectivity : RS232, USB, LAN, HL7 export
  • Internal Battery : ~30 min standalone operation
  • Power Supply : 100 – 240 V AC, 50/60 Hz

highlights

  • Comprehensive ventilation suite covering invasive, non-invasive, and high-frequency ventilation modes.
  • Intuitive touchscreen operation reduces training time and clinical errors.
  • Protective strategies like Volume Guarantee and Smart Pulmonary View for safer neonatal care.
  • Seamless connectivity with hospital IT systems for improved clinical data workflows.
  • Adaptability in clinical environments, from NICU bedsides to integrated respiratory care workflows.

in the box

  • Dräger Babylog VN600 Ventilator Unit
  • Power Supply & Cables
  • Internal Battery & Connectors
  • Patient Circuit Interfaces
  • User Manual & Documentation
  • Optional Accessories (depending on configuration and seller): external battery packs, trolley, additional sensors/cables

Use Cases :

  • Neonatal Intensive Care Units (NICUs) to support preterm and critically ill infants with respiratory failure.
  • Pediatric care where specialized ventilatory support is required.
  • Invasive Ventilation for neonates requiring endotracheal airway support.
  • Non-Invasive Ventilation (NIV) when less aggressive respiratory support is preferred.
  • Oxygen Therapy and High-Flow Support integrated into ventilation workflows.
  • Transport & Emergency Care with battery backup for short movements or outages.

Key Features :

  • Advanced Ventilation Modes: Supports a wide range of modes including pressure controlled (PC-CMV, PC-SIMV, PC-AC), spontaneous breathing modes (SPN-CPAP/PS, SPN-CPAP/VS), high-frequency oscillation with volume guarantee, and apnea ventilation.
  • Lung & Brain Protective Strategies: Volume Guarantee (VG), Smart Pulmonary View, Automatic Tube Compensation (ATC®), and APRV-AutoRelease® designed to safeguard fragile neonatal lungs and reduce lung injury risk.
  • High-Resolution Touchscreen: 15.6″ capacitive glass screen with intuitive interface, configurable views, and step-by-step guidance for easier operation.
  • Leak Adaptation & Sensitive Triggering: Designed to maintain stable pressure delivery even with significant circuit leaks during non-invasive ventilation.
  • Connectivity & Data Management: RS-232, USB, LAN interfaces and support for standardized network protocol and HL7 data export, enabling integration into hospital systems and EMRs.
  • Battery Backup: Internal battery offers brief autonomous operation, with options for extended external battery support.

Warranty

Seller

AA MEDIE QUIPLearn More

Product Description

The Dräger Babylog VN600 is a state-of-the-art neonatal ventilator designed for comprehensive respiratory support in neonatal intensive care units (NICUs) and pediatric settings. It integrates advanced ventilation strategies, lung-protective modes, and intuitive user interaction to provide gentle ye...