Masimo EMMA Handheld ETCO2 Monitor
New0.0|0 Ratings
Quantity :
1
Specifications
- Device Type : Compact, battery-powered quantitative mainstream capnograph
- Measurements : EtCO₂ and Respiratory Rate
- CO₂ Technology : 2-channel NDIR gas analyzer
- CO₂ Measurement Range : 0–99 mmHg / 0–9.9 kPa
- RR Range : 3–150 breaths/min
- CO₂ Accuracy : 0–40 mmHg: ±2 mmHg; 41–99 mmHg: ±6% of reading
- CO₂ Accuracy – : kPa 0–5.3 kPa: ±0.3 kPa; 5.4–9.9 kPa: ±6% of reading
- RR Accuracy : ±1 bpm
- Warm-up / Full Accuracy : Within 15 seconds
- Total System Response Time : <0.7 seconds
- Display Type : 96 × 96 pixel RGB OLED
- Capnogram Sweep : 14.4 seconds
- EtCO₂ Update : Every breath
- RR Update : Every breath
- Battery Type : 2 × AAA alkaline or lithium
- Battery Life – Alkaline : Approx. 5 hours
- Battery Life – Lithium : Approx. 10 hours
- Operating Temperature : −5°C to +50°C
- Storage/Transport Temperature : −40°C to +70°C
- Operating Atmospheric Pressure : 60–120 kPa
- Operating Humidity : <50 hPa H₂O, non-condensing
- Dimensions : 52 × 39 × 39 mm
- Weight : Approx. 65 g with batteries
- Protection Rating : IP44
- Mode of Operation : Continuous
- Electrical Protection : Internally powered / battery powered
- Applied Part : BF, defibrillation proof
- Adult/Pediatric Adapter Dead Space : 6 mL
- Infant Adapter Dead Space : 1 mL
- Adult/Pediatric Adapter Flow Resistance : <0.3 cm H₂O @ 30 LPM
- Infant Adapter Flow Resistance : <1.3 cm H₂O @ 10 LPM
- Routine Calibration : Not required
- CO₂ Measurement Principle : Infrared absorption / NDIR
- CO₂ Measurement Wavelength : 4–5 μm
- Alarm Types : No Breath, Low EtCO₂, High EtCO₂, Clogged Adapter, No Adapter, Zero Adjustment, Low Battery
- Alarm Volume : ≥57 dB(A) and ≤67 dB(A)
highlights
- Portable handheld design
- Mainstream capnography
- Full accuracy within 15 seconds of operation.
- Audible and visual alarms.
- Adjustable high and low EtCO₂ alarm limits.
in the box
- 1 × EMMA Capnograph
- 1 × Pouch
- 1 × Lanyard
- 2 × AAA batteries are specified as part of the EMMA system in the operator's manual.
Use Cases :
- Operating Room (OR)
- Intensive Care Unit (ICU)
- Emergency Department / Emergency Medicine
- Pre-hospital and Emergency Medical Services
- Emergency Patient Transport
- Patient Rooms
- Clinics
- Long-Term Acute Care
- Respiratory Care
- Anesthesia and recovery
- CPR/resuscitation monitoring
- Endotracheal tube placement and monitoring
- Monitoring of adult, pediatric and infant patients
Key Features :
- Portable handheld design – compact and lightweight for mobile monitoring.
- Mainstream capnography – sensor attaches directly to the breathing circuit.
- Measures End-Tidal CO₂ (EtCO₂) and Respiratory Rate (RR).
- Displays a continuous real-time CO₂ waveform/capnogram.
- Full accuracy within 15 seconds of operation.
- EtCO₂ value is updated every breath.
- Respiratory rate is displayed after two breaths and updated every breath.
- Simple interface with one-touch controls.
- Audible and visual alarms.
- Alarms for No Breath/Apnea, Low EtCO₂, High EtCO₂, No Adapter, Clogged Adapter and Low Battery.
- Adjustable high and low EtCO₂ alarm limits.
- Alarm can be silenced for 2 minutes.
- No routine calibration required.
- Battery powered using two AAA batteries.
- Available with Adult/Pediatric and Infant airway adapters.
- IP44 protection against solid objects and water spray.
- Designed for use in challenging environments.
Warranty
Seller
AA MEDIE QUIPLearn More
Product Description
Masimo EMMA® Capnograph is a compact, battery-powered mainstream capnograph designed for quantitative monitoring of End-Tidal Carbon Dioxide (EtCO₂) and Respiratory Rate (RR). It uses a sensor body attached directly to a disposable EMMA Airway Adapter, allowing real-time monitoring without a convent...