Masimo EMMA Handheld ETCO2 Monitor

Shipping time and rates

Shipping about 5-7 days

Masimo EMMA Handheld ETCO2 Monitor

New
0.0|0 Ratings

Quantity :

1

Specifications

  • Device Type : Compact, battery-powered quantitative mainstream capnograph
  • Measurements : EtCO₂ and Respiratory Rate
  • CO₂ Technology : 2-channel NDIR gas analyzer
  • CO₂ Measurement Range : 0–99 mmHg / 0–9.9 kPa
  • RR Range : 3–150 breaths/min
  • CO₂ Accuracy : 0–40 mmHg: ±2 mmHg; 41–99 mmHg: ±6% of reading
  • CO₂ Accuracy – : kPa 0–5.3 kPa: ±0.3 kPa; 5.4–9.9 kPa: ±6% of reading
  • RR Accuracy : ±1 bpm
  • Warm-up / Full Accuracy : Within 15 seconds
  • Total System Response Time : <0.7 seconds
  • Display Type : 96 × 96 pixel RGB OLED
  • Capnogram Sweep : 14.4 seconds
  • EtCO₂ Update : Every breath
  • RR Update : Every breath
  • Battery Type : 2 × AAA alkaline or lithium
  • Battery Life – Alkaline : Approx. 5 hours
  • Battery Life – Lithium : Approx. 10 hours
  • Operating Temperature : −5°C to +50°C
  • Storage/Transport Temperature : −40°C to +70°C
  • Operating Atmospheric Pressure : 60–120 kPa
  • Operating Humidity : <50 hPa H₂O, non-condensing
  • Dimensions : 52 × 39 × 39 mm
  • Weight : Approx. 65 g with batteries
  • Protection Rating : IP44
  • Mode of Operation : Continuous
  • Electrical Protection : Internally powered / battery powered
  • Applied Part : BF, defibrillation proof
  • Adult/Pediatric Adapter Dead Space : 6 mL
  • Infant Adapter Dead Space : 1 mL
  • Adult/Pediatric Adapter Flow Resistance : <0.3 cm H₂O @ 30 LPM
  • Infant Adapter Flow Resistance : <1.3 cm H₂O @ 10 LPM
  • Routine Calibration : Not required
  • CO₂ Measurement Principle : Infrared absorption / NDIR
  • CO₂ Measurement Wavelength : 4–5 μm
  • Alarm Types : No Breath, Low EtCO₂, High EtCO₂, Clogged Adapter, No Adapter, Zero Adjustment, Low Battery
  • Alarm Volume : ≥57 dB(A) and ≤67 dB(A)

highlights

  • Portable handheld design
  • Mainstream capnography
  • Full accuracy within 15 seconds of operation.
  • Audible and visual alarms.
  • Adjustable high and low EtCO₂ alarm limits.

in the box

  • 1 × EMMA Capnograph
  • 1 × Pouch
  • 1 × Lanyard
  • 2 × AAA batteries are specified as part of the EMMA system in the operator's manual.

Use Cases :

  • Operating Room (OR)
  • Intensive Care Unit (ICU)
  • Emergency Department / Emergency Medicine
  • Pre-hospital and Emergency Medical Services
  • Emergency Patient Transport
  • Patient Rooms
  • Clinics
  • Long-Term Acute Care
  • Respiratory Care
  • Anesthesia and recovery
  • CPR/resuscitation monitoring
  • Endotracheal tube placement and monitoring
  • Monitoring of adult, pediatric and infant patients

Key Features :

  • Portable handheld design – compact and lightweight for mobile monitoring.
  • Mainstream capnography – sensor attaches directly to the breathing circuit.
  • Measures End-Tidal CO₂ (EtCO₂) and Respiratory Rate (RR).
  • Displays a continuous real-time CO₂ waveform/capnogram.
  • Full accuracy within 15 seconds of operation.
  • EtCO₂ value is updated every breath.
  • Respiratory rate is displayed after two breaths and updated every breath.
  • Simple interface with one-touch controls.
  • Audible and visual alarms.
  • Alarms for No Breath/Apnea, Low EtCO₂, High EtCO₂, No Adapter, Clogged Adapter and Low Battery.
  • Adjustable high and low EtCO₂ alarm limits.
  • Alarm can be silenced for 2 minutes.
  • No routine calibration required.
  • Battery powered using two AAA batteries.
  • Available with Adult/Pediatric and Infant airway adapters.
  • IP44 protection against solid objects and water spray.
  • Designed for use in challenging environments.

Warranty

Seller

AA MEDIE QUIPLearn More

Product Description

Masimo EMMA® Capnograph is a compact, battery-powered mainstream capnograph designed for quantitative monitoring of End-Tidal Carbon Dioxide (EtCO₂) and Respiratory Rate (RR). It uses a sensor body attached directly to a disposable EMMA Airway Adapter, allowing real-time monitoring without a convent...