New₹64,000₹95,00033% off
Specifications
- Device Type : Heated Respiratory Humidifier
- Model : nice 8010
- Control : Microprocessor-controlled temperature & humidity feedback
- Temperature Settings : Low / Medium / High (Non-invasive control modes)
- Humidity Output : >12 mg/L optimal humidification
- Circuit Compatibility : Heated wire & non-heated breathing circuits
- Alarm System : Audible & visual alarms for temperature deviations & system faults
- Applications : Ventilator, NIV, NCPAP, Bubble CPAP, High-Flow Oxygen
- Patient Range : Adult, Pediatric, Neonatal
- Certifications : ISO 13485, IEC 60601-1, IEC 60601-1-2, ISO 80601-2-74 compatible design
- Flow Range Up to : ~60 L/min invasive; up to ~120 L/min non-invasive
- Temperature Accuracy : ±0.3 °C (typical)
- Warm-up Time : < 30 min typical*
- Weight : ~3 kg (without chamber)*
highlights
- Provides physiological level humidity at body temperature.
- Advanced microprocessor control with real-time feedback.
- Works with heated wire and non-heated breathing circuits.
- Audible and visual alarms for safety.
- Supports multi-mode temperature settings.
- Designed for adult, pediatric, and neonatal use.
in the box
- Main Humidifier Unit
- Power Cable
- Temperature Probe
- Heater Wire Adapter
- User Manual / Instructions
- (Optional) Stand / Mounting Accessories
Use Cases :
- Mechanical Ventilation Support: Conditioned gas during invasive ventilation to protect delicate airway tissues.
- Non-Invasive Ventilation (NIV): Improves comfort and tolerance for CPAP and BiPAP therapies.
- High-Flow Oxygen Therapy: Enhances oxygen delivery with proper humidity to reduce airway dryness.
- Neonatal & Pediatric Respiratory Care: Supports Bubble CPAP and infant ventilation needs.
- General Respiratory Care: For wards, ICUs, and emergency care where warmed, humidified respiratory gas is essential.
Key Features :
- Physiological Humidity Delivery: Provides respiratory gas humidification close to body humidity levels to support mucociliary function and comfort.
- Microprocessor Control: Advanced electronics deliver precise temperature control and rapid response to setting changes.
- Heated & Non-Heated Circuit Compatibility: Works with both heated wire and standard breathing circuits, reducing rain-out and circuit changes.
- Multi-Mode Operation: Non-invasive control modes with Low, Medium, and High temperature settings.
- Audible & Visual Alarms: Alerts clinicians if actual temperature deviates from set limits or there’s a system issue.
- High Humidity Output: Delivers humidity >12 mg/L to help mucociliary clearance and reduce breathing effort.
- Accurate Temperature Feedback: Dual sensors (chamber and airway) provide real-time feedback for consistent humidification.
- Broad Clinical Compatibility: Suitable for adult, pediatric, and neonatal applications (ventilators, NCPAP, Bubble CPAP, infant resuscitation, high-flow oxygen).
Warranty
Seller
AA MEDIE QUIPLearn More
Product Description
The Neotech nice 8010 Heated Respiratory Humidifier is a clinical-grade humidification system designed to warm and moisten respiratory gases delivered to patients in a range of respiratory therapies. It uses advanced microprocessor-controlled heating to provide physiological-level humidity at body t...